ACTIVITIES
MECHANICAL RESISTANCE TESTS (VIBRATION, SHOCK, ACCELERATION)
- Vibration tests (sine, random, sine on random, etc.)
- Search for resonances
- Shock tests and accident safety
- Combined tests (vibration, shock, temperature)
- Linear acceleration
Typical test standards:
ČSN EN 60068-2-6, ČSN EN 60068-2-64, ČSN EN 60068-2-27, ČSN EN 50155, ČSN EN 61373, RTCA/DO-160, MIL-STD-810

CLIMATIC AND CORROSION TESTS

The main activities includes:
-
- Climatic tests (heat, cold, temperature variation, humidity – damp heat cyclic/constant, dust, solar radiation, ozone, vacuum, IP-protection etc.)
- Salt spray corrosion tests, cyclic corrosion tests
Typical test standards:
ČSN EN 60068-2-1, ČSN EN 60068-2-2, ČSN EN 60068-2-14, ČSN EN 60068-2-30, ČSN EN 60068-2-78, ČSN EN ISO 9227, ASTM B117, ASTM G85, PV1200, PV1208, PV1209, RTCA/DO-160, MIL-STD-810
PRESSURE TESTS
Hydraulic pressure tests:
- hydrostatic pressure tests up to 300 MPa
- hydrodynamic pressure tests up to 45 MPa
- destructive tests
Component tests of LPG/CNG systems
Typical tests standards:
ČSN EN ISO 1402, ČSN EN ISO 6803, ČSN 119008, ČSN EN 14276-2, ČSN EN 378-2,
ISO 15500, ECE Regulation No. 67.01, ECE Regulation No.110

TESTING OF ELECTRICAL SYSTEMS

Electrical tests of aircraft systems and other products in accordance with DO-160D and MIL-STD, such as:
- Magnetic effects
- Power supply
- Voltage needle pulses
- Influence of low frequency signals conducted over power lines
- Influence by induced signals
- Influence of transients caused by lightning
- Electrostatic discharge
- etc.
Typical test standards:
RTCA/DO-160, MIL-STD-810
CALIBRATIONS
- Electrical quantities (calibration of multimeters, ammeters, voltmeters, shunt meters, etc.)
● Direct voltage up to 1000 V
● DC up to 300 A
● Alternating voltage up to 700 V
● AC up to 10 A
● Electrical resistance up to 100 MOhm
● Frequency up to 50 MHz - Temperature (-60°C to +180°C)
- Weight (up to 22 kg with a resolution of 1 g)
- Devices and sensors for measuring vacuum up to 70 mbar
- Deformation gauges up to 100 MPa

REVISIONS OF PRESSURE VESSELS

-
Revisions, inspections and tests of pressure equipment in operation.
Approval applies to category NA (pressure vessels with a maximum working pressure exceeding 0,2 MPa and having a safety factor greater than 103), including also category NB (other pressure vessels, which are pressure vessels with a maximum working pressure up to and including 0,2 MPa and having a safety factor less than or equal to 103).